Aperçu ATEX / IECEx

Fondement technique de la conception d'équipements antidéflagrants : comment les atmosphères explosives se forment, comment elles sont classées en zones, et comment les équipements sont marqués selon les normes internationales.

General Technical Information

An explosive atmosphere is defined as a mixture of dangerous substances with air, under atmospheric conditions, in the form of gases, vapours, mist or dust — in which, after ignition has occurred, combustion spreads to the entire unburned mixture.

The three requirements for an explosion:

  1. Flammable gas, vapor or dust within certain limits of concentration
  2. Air containing a minimum concentration of oxygen
  3. An ignition source of minimum temperature and energy
🔥 OXYGEN HEAT FUEL FIRE TRIANGLE
Flammable gasses require only small amounts of energy to react with atmospheric oxygen, such as a spark or hot surface. Therefore, the surface temperature of mechanical and electrical equipment used is also of importance.
Flammable liquids change into vapour phase that forms a potentially explosive atmosphere near their surface. Depending on the properties of each liquid, the proportion that has evaporated into the surrounding air is determined by the temperature of the liquid.
Flammable solids in the form of dust, fibre or flyings can react with atmospheric oxygen and produce significant explosions. Dust layers begin smouldering on hot surfaces, while a dust cloud can explode immediately through contact with a hot surface or by an ignition source.

Temperature Classifications

Protective methods have been developed and defined in standards and regulations around the world to prevent loss of life, serious injuries and significant damage that explosions can cause.

Turkey Regulation

In Turkey, "The Regulation on Equipment and Protective Systems to be Used in Potentially Explosive Environments (94/4/AT)" issued on 30.12.2006 via No. 26392 (4. rev) is in effect. This regulation is in parallel to the European Union Directive 94/9/EC.

EU Directive (ATEX 95)

Directive 94/9/EC — also known as "ATEX 95" or the "ATEX Equipment Directive" — concerns the approximation of the laws of Member States on equipment and protective systems intended for use in potentially explosive atmospheres.

The two widely used ways of reducing the risk of explosion are preventing release of dangerous substances to avoid creation of explosive atmospheres, and in potentially explosive atmospheres, preventing sources of ignition by using Ex-Proof Equipment.

Zone Classification

Probability of a potential explosive atmosphere occurring, mapped to equipment group, category, explosion group and Niveau de Protection de l'Équipement (EPL).

Zone Probability of a Potential Explosive Atmosphere Occurring
Gas Dust
0 20 Always, temporarily or often present.
1 21 Occasionally present.
2 22 Very seldom or only for a short period.
Groupe d'Équipement Catégorie d'Équipement Groupe d'Explosion EPL Zones
I M1 I Ma NA
M2 Mb
III 1G II A Ga 0
2G II B Gb 1
3G II C Gc 2
1D Da 20
2D Db 21
3D Dc 22

Marquage des Équipements Antidéflagrants

Décomposition technique d'une chaîne de marquage d'équipement ATEX / IECEx — ce que signifie chaque segment et comment le lire pour les environnements gaz et poussières.

Voici un schéma technique expliquant le marquage des équipements antidéflagrants (Ex), basé sur les normes ATEX / IECEx.

Gas
ATEX / IECEx equipment marking diagram for gas and dust environments Niveau de Protection de l'Équipement (EPL) Classe de Température Groupe d'Explosion Type de Protection Marquage d'Explosion Aptitude à l'Atmosphère Explosive (G-Gaz) Catégorie d'Équipement Groupe d'Équipement Marquage de Protection Antidéflagrante Ex II 2 G Ex d IIC T6 Gb II 2 D Ex t IIIC T80°C Db IP 6 5 Groupe d'Équipement Catégorie d'Équipement Aptitude à l'Atmosphère Explosive (G-Gaz) Marquage d'Explosion Type de Protection Groupe d'Explosion Classe de Température Niveau de Protection de l'Équipement (EPL) Ingress Protection Rating Protection Against Corps Solides and Dust Protection against liquids
Dust

Not sure which zone or marking applies to your site?

Send us your application details and our engineers will specify the right ATEX configuration for your environment.